2p 4p W362 RCCB RCD Residual Current Circuit Breaker

  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • High Breaking Capacity: Capable of disconnecting short circuits up to 10kA for enhanced safety.
  • IP20 Protective Grade: Features a high protective grade up to IP20 for reliable operation.
  • Long Mechanical Life: Designed for durability with a mechanical life of 10,000 operations.
  • Multi-Pole Assorting: Supports convenient multi-pole configurations for 2 and 4 pole setups.
  • Wide Voltage Range: Rated for AC 240V (single pole) and AC 415V (double/three pole).
  • Multiple Certifications: Certified by VDE, ISO9001-2000, CE, and CB standards.
  • Sensitive Action: Ensures good reliability of sensitive action for effective protection.
  • Versatile Application: Used for overload, short circuit protection, and switching circuits.

Product Images of 2p 4p W362 RCCB RCD Residual Current Circuit Breaker

2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
2p 4p W362 RCCB RCD Residual Current Circuit Breaker pictures & photos
2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker
  • 2p 4p W362 RCCB RCD Residual Current Circuit Breaker
    2p 4p W362 RCCB RCD Residual Current Circuit Breaker

Find Similar Products

Product Description






ID Residual Current Circuit Breaker

Application

ID Residual Current Circuit Breaker is an all new high performance current device with the ability to disconnect short circuits of up to 10kA.Which is the newest model in 21st century.

ID Residual Current Circuit Breaker has many merits of high protective grade(up to lp20),high breaking capacity, good reliability of sensitive action, convenient multi-pole assorting, long using life ect. They are mainly are mainly used for overload and short circuit protection within the circuit of AC50Hz,240V in single pole,415V in double, three & commerce. Meanwhile, they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.




Dimension And Mounting

2p 4p W362 RCCB RCD Residual Current Circuit Breaker


 
Notice

1.Leakage protection function of RCCB is tested and adjusted by the manufacturer, users can not open the product at random during usage.

2.After using RCCB for a certain time (normally one month),test button should be pressed once in a state of making the circuit to check whether the function of RCCB is normal and reliable(press test button once, the RCCB can cut off at once).

3.RCCB must not be wetted or soaked by rain, snow or water during the course of transportation, storation and usage.

4.RCCB can not protect short circuit in application.

Type and
Specification
Rated
Current
Rated
Voltage
Rated
Operating
Current
Residual
Operating
Current range
Rated conditional
Short circuit
Current
Mechanical
life
ID 2 Poles 16A
25A
32A
40A
63A
AC 240V 0.03A
0.1A
0.3A
0.5I Δ n~ I Δ n 3000A to 6000A 10000
ID 4 Poles 16A
25A
32A
40A
63A
AC 415V 0.03A
0.1A
0.3A
0.5I Δ n~ I Δ n 3000A to 6000A 10000

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR263117". Items marked "verified" are certified.

Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.
Yueqing Vebo International Co., Ltd.

About Our Factory & Business Background

Address
No. 26, Lvao Industrial Zone, Liushi, Yueqing, Wenzhou, Zhejiang, China
Terms of Payment
LC, T/T, D/P, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
NINGBO, SHANGHAI

Our Production Capability & Technical Expertise

Main Products
RCCB, MCB, Circuit Breaker, Heavy Duty Connector, Button Switch, Power Supply, RCD, RCBO, Float Switch, LED Indicator

Our Industry Experience & Global Business Record

Export Year
2011-08-08
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum breaking capacity?
The device can disconnect short circuits of up to 10kA.
What are the rated voltages for different poles?
It is rated for AC 240V in single pole and AC 415V in double, three, and commercial setups.
Can the RCCB protect against short circuits?
No, the RCCB cannot protect against short circuits in application; it is primarily for residual current protection.
How often should the test button be pressed?
After using the RCCB for a certain time, normally once a month, the test button should be pressed to check functionality.
Can users open the product for adjustment?
No, the leakage protection function is tested and adjusted by the manufacturer; users must not open the product at random.
What is the mechanical life of the breaker?
The mechanical life is 10,000 operations.
What are the available rated currents?
Available rated currents include 16A, 25A, 32A, 40A, and 63A.
What are the lead times for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now